How to Use the Calibration Board for Sewer3D Scans

Last updated: November 12, 2026

Capture the SewerAI calibration board clearly to provide a known scale reference for Sewer3D measurements. Take an additional physical measurement in the field so you have an independent reference if the board is obscured or the model needs a scale check.

Get the Supported Board

Print the PDF at Actual Size

  1. Download and open the PDF.

  2. Select Tabloid / 11 x 17 inch paper.

  3. Print at Actual Size / 100%. Turn off Fit to page, Shrink or other automatic scaling.

  4. Before using the board, check the printed target spacing against the known distances below and confirm that all targets are complete and visible.

Do not print a screenshot or the web preview as the calibration board. Use a durable board for ongoing field work.

Position It for the Scan

  1. Place the board near the rim or opening and the measurement plane when practical, while keeping every target fully visible.

  2. Keep it upright, stationary and as perpendicular to the camera's center line as practical. Avoid a steep angle.

  3. Check that targets are not obscured by dirt, water droplets, glare or a 360-degree image seam.

  4. Keep the board still while filming.

  5. Record at least one additional fixed field measurement as a backup.

There is no hard maximum board-to-rim distance. Placement far down the shaft can bias the scale toward that depth, making it less representative of measurements near the rim. Prioritize a clear, stable reference near the area you need to measure.

Preview of the printable SewerAI calibration board for 11 by 17 inch paper

Preview only. Download and print the PDF at actual size rather than printing this web image.

Understand the Reference Distances

The supported calibration reference includes target distances of 18 cm, 24 cm and 30 cm. Compare the measured endpoints with the correct known distance for those targets, rather than assuming every pair has the same spacing.

  • Markers 1 to 2: 30 cm.

  • Markers 1 to 3: 24 cm.

  • Markers 2 to 3: 18 cm.

Verify the Generated Model

Before relying on a model's dimensions, compare a visible reference with its known physical measurement. If the board was not captured clearly, a reliable known dimension, such as the cover size, can provide a fallback scale reference.

Follow the point-cloud measurement and scale guide to verify or adjust scale. Viewing and measuring are separate from saving scale changes. Do not enter a calibration-marker or cover dimension as the value of a different feature, such as the frame or chimney.

A manual scale adjustment changes inspection measurement values. It does not change the geometry drawn in the viewer or in downloadable LAS/GLB files.

If no reliable reference or necessary endpoints are visible, or measurements remain inconsistent, contact Support rather than guessing. Keep the recording and independent field measurements available.

Related Guides

Still Need Help?

Use the chat widget in PIONEER to contact our support team.

If you cannot access the chat widget, email help@sewerai.com.