Troubleshooting Footage Counter Issues in Pioneer
Last updated: May 20, 2025
If your footage counter is not working properly in PIONEER, follow these troubleshooting steps to resolve common issues.
For IBAK Systems with Soft Controls
If you're using an IBAK system with soft controls:
Run both Pioneer and Soft Controls as Administrator
Ensure you're using the latest version of Pioneer (Alpha or Beta if recommended by our support team)
If the counter freezes between inspections, try closing and reopening Pioneer
Verify the Soft Controls application is fully loaded and presenting the counter data
For Systems Using COM Ports
If your system uses direct COM port connections:
Check that the correct COM port is selected in Pioneer settings
If the counter stops working, the COM port may have changed - verify the current port number
Ensure all cables are properly connected between the counter and computer
General Troubleshooting
Verify the counter is working properly on your controller/hardware before checking Pioneer
For calibration issues, measure out 25 feet of cable and perform a calibration in Pioneer
If switching between mainline and lateral inspections, you may need to reconfigure counter settings
When to Contact Support
Contact support if:
The counter works on your controller but not in Pioneer
Calibration attempts don't resolve the issue
The counter freezes consistently between inspections
You need to recover distance data from a recorded inspection
Note: If footage data is missing from an already uploaded inspection, it typically cannot be recovered unless the original distance file can be located on the recording system. Contact support for more help with this issue.